F SeriesPure sine wave power inverter

Inverter hery



Features:

• Double MCU intelligent design, excellent performance

• Comprehensive digital LCD display, easy to understand the working state of the machine

• Wide input voltage range, high precision output, full automatic voltage stabilization function

• Battery type/ charging current selection meet different requirement of battery

• Municipal priority mode/energy-saving mode/battery priority mode can be set

• Comprehensive protection function

• Pure sine wave output compatible with different types of loads.

Features

Technical Data

Request information

————————————————————————————————————————————————————————————————————————————

Solar System Connection

F series Low frequency power inverter is a multi-function off grid pure sine wave power inverter, built in Utility battery charger offering uninterruptible power supply for home use. Timing DC/AC mode and accepting various type of battery meet different requirements. High-end touch screen offer user-configurable and easy accessible button setting like battery type, battery charging current, Utility power priority and wide range of AC input voltage based on different applications.

    Model F 500W F 1KW F 2KW F 3KW F 4KW F 5KW F 6KW
    Default battery voltage system 12V/24V/48V 24V/48V
    Working Mode DC Priority/ AC priority( UPS mode) optional
    INVERTER OUTPUT
    Rated power 500W 1000W 2000W 3000W 4000W 5000W 6000W
    Suger power(20 ms) 1500W 3000W 6000W 9000W 12000W 15000W 18000W
    Waveform Pure Sine Wave
    AC Voltage Regulation( Battery Mode) 165V~275V or 72Vac~137Vac
    Inverter efficiency >86%(80% Resistive Loads)
    Transfer Time ≤3ms
    Over Load Protection 110%~120% in 10s, >120% in 3s
    Wave Form Distortion linear load ≤3%
    Protection feature Battery high voltage, battery low voltage, overload, short circuit, over temperature, etc.
    BATTERY
    voltage optional 12Vdc/24Vdc/48Vdc 24Vdc/48Vdc
    Charge current 30A~60A in Max (Setable according to battery capacity)
    Battery type Gel AGM, Lead acid. Calcuim
    Mains Status
    Input PF. (AC/DC) 0.9
    Mains Overload warming until decrease load
    Alarm
    Mains Abnormal 1 time/1S, silence auto after 5S
    Low Battery 1 time/1S and flash battery last grid
    Overload 1 time/1S and display" overload" grid
    MECHANICAL SPECIFICATIONS
    Machine Dimensions (W*H*D)(mm) 520*280*180 560*310*180
    Net Weight(kg) 10 13 16.5 19.2 24.5 26.5 29.5
    OTHER
    Display LCD+LED (Input Voltage, Output Voltage, Output Frequency, Battery Capacity, Inductive Load Power)
    Cooling method Fans Cooling
    Audible Noise 45DB MAX
    Humidity 5% to 95% Relative Humidity( Non-condensing)
    Operating Temperature 0°C ~ 60°C
    Storage Temperature -15°C ~ 60°C
    Standard Warranty 2 year
    DC volatge operating parameters (AC power priority working mode)
    Battery System Voltage High voltage protection Low volatge alarm Low voltage shutdown
    12Vdc System 15.0V 10.5V 10.0V
    24Vdc System 35.0V 22.0V 20.5V
    48Vdc System 65.0V 42.0V 41.0V
    DC volatge operating parameters (DC power priority working mode)
    Battery System Voltage High voltage protection Low volatge alarm Low voltage shutdown To DC priority mode
    12Vdc System 15.0V 10.5V 10.0V 13.5V
    24Vdc System 35.0V 22.0V 20.5V 27.0V
    48Vdc System 65.0V 42.0V 41.0V 54.0V
    *Products specifications are suject to change without further notice